How do I remove and prepare a container for return to Avantor Performance Materials?
Answer
Follow the container removal steps:
  1. Close the solvent valve (VS) first to prevent back flushing into the container.
  2. Close the gas valve (VG).
  3. Remove all customer-owned equipment.
  4. Disconnect the gas and solvent quick-connects (QCG and QCS) and replace the dust caps on both quick-connect male stems on the container.
  5. If applicable, disconnect the liquid level indicator connection (LC) and the pressure relief vent lines from the container.
  6. Disconnect the facility grounding cable from the CYCLE-TAINER grounding terminal (GT).
  7. Replace the transport cap for the pressure relief valve (PRV).
  8. Replace the transport cover for the pressure rupture disk assembly (PRDA), if applicable.
  9. Reseat the container dust cover.
  10. Reseal the container dust cover with tamper evident straps that arrived in the chime at the time of receipt.

The container can now be moved to your shipping area for return shipment. Before shipping the container, use the return shipment checklist (attached)to ensure proper shipment. The completed checklist can be kept for your records.

 

 

 

Trademarks are owned by Avantor Performance Materials, LLC. or its affiliates unless otherwise noted.
2018 Avantor Performance Materials, LLC.

 

Please be aware that if you are using an older version of Adobe Acrobat Reader (5.0 or earlier, for example) the information in the attached files may not display correctly. If needed, you can visit the Adobe homepage to download the most current version of the Adobe Reader software free of charge: Adobe.com

KeywordsCTS

Feedback

 

Was this article helpful?


   

Feedback

Please tell us how we can make this article more useful.

Characters Remaining: 255